How many fixtures need to be installed in the classroom?

Ivan asks:
Good afternoon. How many fixtures are needed in the classroom according to the norms. Provided that the room is 10 by 70 by 3m. 36W 2800lm luminaires?
The answer to the question:
Good afternoon, according to SanPiN 2.4.2. 2821-10 clause 7.2.4 illumination at the level of tables should be in the range of 300-500 Lux. If we calculate the illumination roughly according to the area, then each lamp produces 2800 Lm, 1 lux is 1lm / 1 m², with an area of ​​700 m² for illumination of 300 Lx it is necessary to provide a total luminous flux (Lx * m²) of 210,000 Lm. This means that you need 210000/2800 = 75 of these fixtures. But this is a very rough calculation, although approximately the same amount will be installed, I believe - every 2 meters in the lamp in 2 rows ...
Loading...