What should be the wiring in the house for everything to work?

Good afternoon! The wiring goes from the pillar to a Soviet-built private house. Please tell me what section the wire should go from the entrance to the house to the counter with bags so that modern equipment works and does not knock it out (now when you turn on several devices at the same time (for example, a kettle and a boiler knocks out), what meter and bags should be. housework outdoor?

Loading...

One comment

  • Admin

    Hello! Initially, everything is limited to a circuit breaker installed on the input, as well as allocated power to the house. From this they are already dancing further. In order not to knock anything out and you could turn on several powerful consumers at the same time, an automaton with 25A or more should be on the input. In this case, the cable for entering the house should be a cross-section of 4 mm.kv. (copper), even 6 squares is better. Then they put group automata: into the light of 10A, into rosette groups (there should be several) 16A each. In this case, a cable with a cross section of 1.5 mm.sq. is used for light, and 2.5 mm.sq. for sockets. Put a single-phase electric meter to withstand up to 60A, this is enough with your head.

    To answer

Add a comment