    Yes you can. But, in any case, you need to look in the terminal block of this panel - for some countries the terminal block may differ. If it is possible to connect to two or three phases, then there must be three phase outputs in the terminal block of the hob. There should be a connection diagram near the terminal block - 1N - connection to one phase, 2N - to two phases, 3N - to three phases.
    When connected to one phase, all three phase outputs of the hob are connected by a jumper, and when the hob is connected to two phases, one phase is connected to one phase output and the other phase to two others connected by a jumper - the diagram indicates which phase outputs the jumper is connected to .
    When connecting, it is important to choose the right cable so that it can withstand the load that will be on each of the phases.